Italtext Premium (heavy duty) Extra Pure
SHORT DESCRIPTION
Italtext Premium (Heavy Duty) Extra Pure is a specialized industrial-grade formulation designed for high-performance cleaning, degreasing, or maintenance applications in laboratories, workshops, and technical environments. Known for its powerful action and superior purity, it effectively breaks down heavy soils, stubborn residues, and oily contaminants without compromising sensitive surfaces. This heavy-duty product is ideal for use in precision equipment care, lab bench sanitation, and pre-treatment of surfaces requiring strict cleanliness. Its “Extra Pure” classification guarantees consistent results with minimal interference in analytical or sensitive processes, making it a reliable choice for demanding professional settings.
USES
Primary Laboratory Uses:
- Heavy-Duty Laboratory Cleaning Agent:
Specifically formulated for removing stubborn residues such as grease, oils, biological matter, and chemical films from laboratory glassware, metal instruments, and surfaces. - Glassware and Apparatus Preparation:
Extensively used in labs for pre-cleaning glassware before sensitive analytical procedures, especially where trace contaminants could interfere with results (e.g., spectroscopy or chromatography). - Decontamination in Industrial and Scientific Settings:
Utilized to decontaminate surfaces and tools in research labs, especially in microbiology, biochemistry, and pharmaceutical labs.
Secondary Laboratory Uses:
- Post-Experiment Equipment Maintenance:
Employed after experiments to thoroughly clean equipment and maintain longevity of lab tools and machinery. - Pre-Sterilization Cleaning Step:
Acts as a first step before autoclaving or sterilization, ensuring surfaces are free of organic and inorganic debris. - Routine Lab Hygiene Protocols:
Used in maintaining cleanroom and laboratory hygiene standards, particularly in regulated environments such as GMP/GLP labs.
KEY ATTRIBUTES
1. Basic Identification Attributes
- Product Name: Italtext Premium (Heavy Duty)
- Grade: Extra Pure (Laboratory-grade formulation)
- Type: Proprietary heavy-duty lab cleaner/degreaser
- Physical Form: Liquid or gel (usually clear to slightly cloudy)
- Odor: Mild chemical or citrus-based (varies by formulation)
- Manufacturer/Brand: Italtext (assumed proprietary brand)
2. Composition
- Main Components (typical):
- Non-ionic surfactants (e.g., alcohol ethoxylates)
- Anionic surfactants (e.g., sodium alkyl sulfates)
- Alkaline agents (e.g., sodium metasilicate, sodium carbonate)
- Solvents (e.g., glycol ethers or isopropanol)
- Sequestering agents (e.g., EDTA or phosphates)
- Note: Exact formulation is proprietary; consult MSDS/SDS if available.
3. Physical & Chemical Properties
- pH: Typically alkaline (9–12)
- Density: ~1.00–1.10 g/cm³
- Solubility: Completely water-soluble
- Boiling Point: >100 °C (aqueous base)
- Stability: Stable under recommended lab storage conditions
4. Safety & Hazard Attributes
- GHS Classification:
⚠️ Irritant (due to alkaline agents and surfactants) - Hazard Statements (Likely):
- H315: Causes skin irritation
- H319: Causes serious eye irritation
- H335: May cause respiratory irritation (if mist or vapor is inhaled)
- PPE Requirements:
- Safety goggles or face shield
- Nitrile or neoprene gloves
- Lab coat
- Use in well-ventilated areas or under fume hood for misting applications
- First Aid Measures:
- Skin Contact: Wash thoroughly with soap and water
- Eye Contact: Rinse cautiously with water for several minutes
- Inhalation: Move to fresh air; seek help if breathing difficulty develops
- Ingestion: Rinse mouth and seek medical advice
- Fire Hazards:
- Generally non-flammable (aqueous base)
- Use appropriate extinguishing media if involved in fire
5. Storage & Handling Attributes
- Storage Conditions:
- Store tightly sealed in original container
- Keep in a cool, dry place
- Avoid contact with strong acids or oxidizers
- Handling Tips:
- Do not mix with acidic cleaners or bleach
- Use only as directed for lab cleaning applications
- Ensure containers are closed when not in use
6. Laboratory Applications
- Primary Uses:
- Cleaning and degreasing of glassware, instruments, and lab surfaces
- Removal of organic residues, oils, and contaminants
- Preparation of surfaces before sterilization or coating
- Secondary Uses:
- CIP (clean-in-place) procedures in pilot labs
- Maintenance of equipment used in chemical, pharmaceutical, or food-grade labs
- Controlled cleaning in research facilities requiring residue-free results
SAFETY PRECAUTIONS
Personal Protective Equipment (PPE):
- Wear chemical-resistant gloves, safety goggles, and a lab coat.
- Use a face shield in case of splashing risk.
- Work under a chemical fume hood or in a well-ventilated area.
Handling:
- Avoid contact with skin, eyes, and clothing.
- Do not breathe vapors, spray, or mist.
- Use only with adequate ventilation.
- Wash thoroughly after handling.
- Keep away from food and drink.
Storage:
- Store in a tightly closed, properly labeled container.
- Keep in a cool, dry, and well-ventilated place.
- Protect from heat, sparks, and open flames.
- Avoid storing near oxidizing agents or strong acids.
FIRST AID MEASURES
Inhalation:
- Remove the person to fresh air immediately.
- If breathing is difficult, administer oxygen.
- Seek medical attention if symptoms persist.
Skin Contact:
- Wash skin thoroughly with soap and water.
- Remove contaminated clothing and wash before reuse.
- Get medical attention if irritation or burns occur.
Eye Contact:
- Rinse cautiously with clean water for at least 15 minutes.
- Remove contact lenses if easy to do.
- Seek medical help immediately.
Ingestion:
- Rinse mouth thoroughly with water.
- Do not induce vomiting.
- Seek immediate medical attention and show the product label if possible.
FIRE FIGHTING MEASURES
Flammability:
- May be combustible depending on formulation—check SDS for confirmation.
Extinguishing Media:
- Use carbon dioxide (CO₂), dry chemical, or alcohol-resistant foam.
- Do not use water jet directly on fire.
Hazardous Combustion Products:
- Can emit toxic fumes including carbon monoxide (CO), carbon dioxide (CO₂), and unidentified organic compounds.
Firefighter Protection:
- Wear full protective gear with self-contained breathing apparatus (SCBA).
- Cool containers with water spray to prevent pressure buildup and rupture.
Related products
Albumen from Egg Powder Extra Pure
Aluminium Carbonate Extra Pure
Aluminium Chloride Hydrated Extra Pure
Aluminium Oxide Active Neutral Extra Pure
Ammonia Solution Extra Pure
Ammonium Carbonate Extra Pure
Ammonium Cupric Chloride Extra Pure